We are offering Off-Line UPS.
Capacity: 400-1200VA
KEY FEATURES
Optional function
Line Surge Protection: RJ11/RJ12/RJ45, Communication Interface: RS232
Function & Characteristic:
AVR,Overload and short circuit protection
Low battery alarm, LED status display
UPS Auto on when AC back, Night charging(optional)
APPLICATION
Home, computer

Input Voltage Range 80~140VAC/145~280VAC
Frequency 50/60Hz
Output Voltage Range 110/220VAC ±10%
Frequency 50Hz ±5%
Transfer time < 10ms
Battery Type Sealed free maintenance lead acid battery
Capacity 12V,4AH *1PCS 12V,7AH *1PCS 12V,7AH *1PCS 12V,9AH *1PCS 12V,7AH *2PCS 12V,9AH *2PCS
Recharge Time 8 hrs to 90% of capacity full load discharge
Protection Auto protect
Back-up time(half load) 5~7 min 8~10 min 7~9 min 8~10 min 8~10 min 13~15 min
Function Auto voltage output on AC mode, Auto shutoff if short circuit or overload
DB-9 port,communication software Optional
Protection AC mode Fuse
Short circuit AC Fuse
Invert mode Auto protect
Alarm Alarm Battery discharge Alarm beeps every four seconds
Low battery voltage Alarm beeps every second
Overload Alarm beeps continuously
Indicator light Auto adjust Green lighting: AC mode
Battery Discharge Red lighting: Battery mode
Environment Operating temperature 0?~40?
Operating Humidity 0-90% non-condensing
Noise <35dB(1 meter distance)
From: Longrise Technology International Co Ltd
Posted on: 7/4/2009 7:57:56 PM
Expiring On: 12/31/2009 7:57:56 PM
Days Left: (-777 days to go!)

Description
We are offering Off-Line UPS.
Capacity: 400-1200VA
KEY FEATURES
Optional function
Line Surge Protection: RJ11/RJ12/RJ45, Communication Interface: RS232
Function & Characteristic:
AVR,Overload and short circuit protection
Low battery alarm, LED status display
UPS Auto on when AC back, Night charging(optional)
APPLICATION
Home, computer

Input Voltage Range 80~140VAC/145~280VAC
Frequency 50/60Hz
Output Voltage Range 110/220VAC ±10%
Frequency 50Hz ±5%
Transfer time < 10ms
Battery Type Sealed free maintenance lead acid battery
Capacity 12V,4AH *1PCS 12V,7AH *1PCS 12V,7AH *1PCS 12V,9AH *1PCS 12V,7AH *2PCS 12V,9AH *2PCS
Recharge Time 8 hrs to 90% of capacity full load discharge
Protection Auto protect
Back-up time(half load) 5~7 min 8~10 min 7~9 min 8~10 min 8~10 min 13~15 min
Function Auto voltage output on AC mode, Auto shutoff if short circuit or overload
DB-9 port,communication software Optional
Protection AC mode Fuse
Short circuit AC Fuse
Invert mode Auto protect
Alarm Alarm Battery discharge Alarm beeps every four seconds
Low battery voltage Alarm beeps every second
Overload Alarm beeps continuously
Indicator light Auto adjust Green lighting: AC mode
Battery Discharge Red lighting: Battery mode
Environment Operating temperature 0?~40?
Operating Humidity 0-90% non-condensing
Noise <35dB(1 meter distance)