Aeo Energy Technology Co.,Ltd.
|
Sell
|

The stand-alone inverter is designed for new energy generating system, mainly for solar photovoltaic power plants, wind power generation power plants, the hybrid power generation system of wind, solar, diesel oil and energy-storage.Product’s power from 500W-10KW. Features 1. Use integrated circuit, less wire connection. 2. With high efficiency transformer instead of high frequency e-circuit design 3. LCD display 4. Buzzer alarm while over-loading/voltage, high-temperature
Technical Parameter Model SI05-24 Rated Output Power 500W Rated DC Input Voltage 24 VDC Over Voltage Shutdown 34 VDC Over Voltage Recovery 33 VDC Under Voltage Shutdown 21 VDC Under Voltage Recovery 24 VDC No Load Loss 0.4A Output Wave Pure Sine Wave Rated Output Voltage 110/120/220/230/240 VAC Total Harmonic Distortion =4% Output Frequence 50/60 Hz±0.05Hz Dynamic Response 5% Over-load Capacity 120%,1min 150% 10s Inverter Efficiency 90% Noise Level =40dB (1m) Isolate Level 1500VAC,1min Working Environment Temperature -10~50?,Altitude =4000m, Humidity 0~90%,no condensing Protection Type "high battery, low battery, over load , short circuit, over temperature, pole-confusion protection for storage
From: Aeo Energy Technology Co.,Ltd.
Posted on: 6/30/2009 7:39:24 AM
Expiring On: 12/27/2009 7:39:24 AM
Days Left: (-782 days to go!)
 |
| Description |
The stand-alone inverter is designed for new energy generating system, mainly for solar photovoltaic power plants, wind power generation power plants, the hybrid power generation system of wind, solar, diesel oil and energy-storage.Product’s power from 500W-10KW. Features 1. Use integrated circuit, less wire connection. 2. With high efficiency transformer instead of high frequency e-circuit design 3. LCD display 4. Buzzer alarm while over-loading/voltage, high-temperature
Technical Parameter Model SI05-24 Rated Output Power 500W Rated DC Input Voltage 24 VDC Over Voltage Shutdown 34 VDC Over Voltage Recovery 33 VDC Under Voltage Shutdown 21 VDC Under Voltage Recovery 24 VDC No Load Loss 0.4A Output Wave Pure Sine Wave Rated Output Voltage 110/120/220/230/240 VAC Total Harmonic Distortion =4% Output Frequence 50/60 Hz±0.05Hz Dynamic Response 5% Over-load Capacity 120%,1min 150% 10s Inverter Efficiency 90% Noise Level =40dB (1m) Isolate Level 1500VAC,1min Working Environment Temperature -10~50?,Altitude =4000m, Humidity 0~90%,no condensing Protection Type "high battery, low battery, over load , short circuit, over temperature, pole-confusion protection for storage |
|
|
 |
|
|